How Heat Pump Works. Window and Through-Wall.
Room air conditioners come in two forms: unitary and packaged terminal PTAC systems. Unitary systems, the common one room air conditioners, sit in a window or wall opening, with interior controls. Interior air is cooled as a fan blows it over the evaporator. On the exterior the air is heated as a second fan blows it over the condenser. In this process, heat is drawn from the room and discharged to the environment. A large house or building may have several such units, permitting each room to be cooled separately.
PTAC systems are also known as wall split air conditioning systems or ductless systems. These PTAC systems which are frequently used in hotels have two separate units (terminal packages), the evaporative unit on the interior and the condensing unit on the exterior, with tubing passing through the wall and connecting them. This minimizes the interior system footprint and allows each room to be adjusted independently. PTAC systems may be adapted to provide heating in cold weather, either directly by using an electric strip, gas or other heater, or by reversing the refrigerant flow to heat the interior and draw heat from the exterior air, converting the air conditioner into a heat pump. While room air conditioning provides maximum flexibility, when used to cool many rooms at a time it is generally more expensive than central air conditioning. The first practical through the wall air conditioning unit was invented by engineers at Chrysler Motors and offered for sale starting in 1935.
What is a Mini Split Heat Pump? Window Unit.
Evaporative cooler In very dry climates, evaporative coolers, sometimes referred to as swamp coolers or desert coolers, are popular for improving coolness during hot weather.
An evaporative cooler is a device that draws outside air through a wet pad, such as a large sponge soaked with water. The sensible heat of the incoming air, as measured by a dry bulb thermometer, is reduced. The total heat (sensible heat plus latent heat) of the entering air is unchanged. Some of the sensible heat of the entering air is converted to latent heat by the evaporation of water in the wet cooler pads. If the entering air is dry enough, the results can be quite cooling; evaporative coolers tend to feel as if they are not working during times of high humidity, when there is not much dry air with which the coolers can work to make the air as cool as possible for dwelling occupants.
Unlike other types of air conditioners, evaporative coolers rely on the outside air to be channeled through cooler pads that cool the air before it reaches the inside of a house through its air duct system; this cooled outside air must be allowed to push the warmer air within the house out through an exhaust opening such as an open door or window. These coolers cost less and are mechanically simple to understand and maintain. An early type of cooler, using ice for a further effect, was patented by John Gorrie of Apalachicola, Florida in 1842. He used the device to cool the patients in his malaria hospital.
Heat Pumps Residential. Heat pumps.
"Heat pump" is a term for a type of air conditioner in which the refrigeration cycle can be reversed, producing heating instead of cooling in the indoor environment. They are also commonly referred to, and marketed as, a "reverse cycle air conditioner". Using an air conditioner in this way to produce heat is significantly more energy efficient than electric resistance heating. Some homeowners elect to have a heat pump system installed, which is simply a central air conditioner with heat pump functionality (the refrigeration cycle can be reversed in cold weather). When the heat pump is in heating mode, the indoor evaporator coil switches roles and becomes the condenser coil, producing heat. The outdoor condenser unit also switches roles to serve as the evaporator, and discharges cold air (colder than the ambient outdoor air).
Heat pumps are more popular in milder winter climates where the temperature is frequently in the range of 40 – 55°F, because heat pumps become inefficient in more extreme cold. This is due to the problem of ice forming on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to being the condenser coil, so that it can heat up and defrost.
Heat Pump for Cooling. Absorption Heat Pumps.
Absorption heat pumps are actually a kind of air-source heat pump, but they do not depend on electricity to power them. Instead, gas, solar power, or heated water is used as a main power source. Additionally, refrigerant is not used at all in the process.[dubious – discuss] An absorption pump absorbs ammonia into water.[further explanation needed] Next, the water and ammonia mixture is depressurized to induce boiling, and the ammonia is boiled off, resulting in cooling.
Some more expensive window air conditioning units have a true heat pump function. However, a window unit that has a "heat" selection is not necessarily a heat pump because some units use only electric resistance heat when heating is desired. A unit that has true heat pump functionality will be indicated its specifications by the term "heat pump".