Get Copper Line Set for Ductless Systems.

Major advantages include:

Installation is quick, efficient, and economical.
The continuous, factory-applied insulation has no seams which can open to allow moisture entry, bothersome dripping and decreased system efficiency.
Tubes can be supplied in custom lengths for each job, reducing waste.
Factory assembly assures quality and consistency.

PRICE: $99.99 ex. tax

Air Conditioning and Refrigeration Tube

Line-sets are copper tubing lines used to connect split system air conditioners and heat pumps. The two copper lines (liquid line and suction line) in the set are refrigerant lines that connect the condensing unit (air conditioner-outside) to the evaporator coil (e-coil) in the furnace unit. The line-set tubes are Pre-Flared & Pre-Insulated using ACR Tube or a Level Wound Coil (LWC).

*See related items below. 

Pre-Flared & Pre-Insulated Line-Set: Line-sets are provided with a pre-insulated suction line paired with a bare liquid line in a convenient package. Line-sets have come into wide use in most areas of the country because they offer a better way to field connect split system air conditioners and heat pumps.

Major advantages include:

  • Installation is quick, efficient, and economical.
  • The continuous, factory-applied insulation has no seams which can open to allow moisture entry, bothersome dripping and decreased system efficiency.
  • Tubes can be supplied in custom lengths for each job, reducing waste.
  • Factory assembly assures quality and consistency.

All Air Conditioning and Refrigeration Tubes are produced with lubricants tested for all freon compatibility and formicary corrosion tested.

ACR Tube : Liquid line and suction line can be field constructed and insulated using our superior clean and plugged ACR tube.

This is typically for applications where a rigid straight tube provides the best solution for installation, such as commercial refrigeration applications.

LWC : Seamless smooth wall level wound copper tube is produced from a cathode based cast & roll process. A Level Wound Coil (LWC) is a long length of tube that is uniformly and tightly spooled in layers parallel to the axis of the coil. LWCs that require annealing are produced in our ultra clean annealing furnace which yields superior ID cleanliness. LWCs are used for a wide variety of applications in many industries.

Get SPB-66 Condensate Pump for Ductless Mini Split Systems.

Features:

Thermally Protected
Overflow Alarm Function
Suitable water Temp 32°F – 167◦F
Automatic Tank Cleaning
Error Alarm
Anti-Mold Tank
*External Mounting for Easy Servicing

PRICE: $89.99 ex. tax

SPB-66 Condensate Pump for Ductless Systems

SPB-66 SMART PUMP condensate pump is designed as an automatic condensate removal pump for water dripping off an air conditioner evaporative coil. The pump is controlled by a float/switch mechanism which turns the pump on when approximately 2″ of water collects in the tank, and automatically switches off when the tank drains to approximately 1″.

°Compare to more expensive brands like:
⇒Refco’s Gobi II & Aspens ASP-MW-UNI
⇓Scroll Down to related items for other options⇓

Features
Thermally Protected
Overflow Alarm Function
Suitable water Temp 32°F – 167◦F
Automatic Tank Cleaning
Error Alarm
Anti-Mold Tank
*External Mounting for Easy Servicing

TECHNICAL DATA
• Pump rating: 110-240VAC 50/60Hz Single Phase
• Max. water flow rate : 40L / 10.6 US Gal / H
• Max rec. head: 20m / 66ft
• Max.suction lift: 1m / 3.3ft
• Sound level: 19dB(A)@ 1m
• Rated: Non-continuous
• Class: II appliance
• Safety switch: 3A normally closed
• Max.water temperature :70℃ / 158°F
• Inlet size: Ø 7.5mm 
• Outlet size: Ø 7.5mm 
•IP Protection: IPx1
•Thermal Protection: √
•Fully Potted: √
•Self Priming: √


READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THE SMART PUMP. KNOW THE PUMP APPLICATION, LIMITATIONS AND POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
WIRING
INSTRUCTIONS

*Please see the dropdown box above to choose the correct size filter for your system.

Filters for a wall mounted indoor unit are sold in a set of 2.

Filters for a ceiling cassette, ducted, console & floor ceiling are sold as 1pc.  

Please provide the make and model of your system in the additional information box just before checkout. *Once you have completed checkout, we will need a picture of your old filters and the measurements of those filters in order to find a match.

Get CG 4.5” Expandable Line Cover Heavy Duty by CoverGuard.

What’s Included:
air conditioning channel animated-350x (3)
4′ Ducts
(2) Couplers
(1) Wall Inlet
(1) End Cap
(1) 90° Elbow
(13) Cam Screws
(6) Clips

PRICE: $185.99 ex. tax

Kit includes:
air conditioning channel animated-350x(3) 4′ Ducts
Couplers(2) Couplers
Inlet(1) Wall Inlet
End Cap(1) End Cap
90° Elbow(1) 90° Elbow
Cam Screws(13) Cam Screws
Clips(6) Clips

Cover Guard Line Set Cover Features


Listed below are standard features for Cover Guards unique line set cover system.Guards single size expands in depth to save you time and money. The multi zone mini split solutionCover Guard is heavy duty, its the strongest line set cover on the market
  • The Cover Guards 4-stage adjustability is perfect to accommodate multiple zone line sets and allow the duct to expand from 2 to 4 inches deep.
  • Stay-Clean peel-n-go film allows for a no-fuss clean-up following an install. 
  • Free-sliding zip-tie clips are pre-installed, relocating quickly and easily to position the zip tie where its needed most.
  • Components are paintable (see instructions for painting directions).
  • Components are UV stabilized and tested to temperatures from -4 degrees F to 140 degrees F.
  • Cover Guard components do not release under pressure. In fact, the greater the pressure exerted against the inside walls, the tougher the structure becomes, because the pressure causes the pieces to lock more tightly.
  • Fittings can be opened and closed as needed, so the system can be adjusted as necessary at any time.
  • Cam screws are constructed of hardened gun stock plastic. They will never rust. Quarter turn of the screw locks it in place for quick installation.
  • NEW 36” FLEX ELBOW OPTION: Using the adapters on either end, you can put this between two straight pcs and go around corners, or make bends that a normal elbow will not do. 

Ordering with a system?
Use the Following Coupon Code to get $29.99 OFF:  CGKIT
(Coupon Only Valid with Qualified Systems)

*See related items below for other options.

Freon R410A 25 lb. in Minisplitwarehouse.com Choose from more than 300 products that suits your needs exactly! Get Freon R410A 25 lb. Jug Factory Sealed. Price: $549.10 ex. tax. Call us 877-770-3548 or visit our website.

LINK:
https://www.minisplitwarehouse.com/category/accessories

https://www.minisplitwarehouse.com/page/mini-split-systems



There are several brands being marketed as R-410A. Brands vary based on our suppliers but the chemical makeup does not. The more commonly known are Suva® R-410A by DuPont and Puron® by Carrier. These and others have the same ASHRAE number R-410A.

Important Note: R-410A can only be used in equipment designed for R-410A. R-410A cannot be used to retrofit existing R-22 a/c equipment due to significantly higher operating pressures and much higher cooling capacity as outlined in the chart below.

To ensure safe handling of R-410A, remember that the head pressure is significantly higher than R-22. Also, special service equipment is required, including a high-pressure manifold gauge set, high-pressure recovering machine and a high-pressure recovery tank (4BW400).

When handling R-410A, standard fluorocarbon refrigerant safety and handling practices should be followed. Use gloves, safety glasses and safety shoes when handling containers. Avoid skin and eye contact with liquid refrigerant. Work in well-ventilated areas. Vapors are heavier than air and might concentrate near the floor or in low areas.

Storage requirements for R-410A containers are the same as for R-22 and other commonly used refrigerants. Cylinders should be stored in a clean, dry area, out of direct sunlight. Keep valves tightly closed and valve caps and hoods in place when cylinder is not in use.

Because of its enhanced properties, R-410A systems will operate differently than R-22 systems.

PropertiesR-410A
Discharge Pressure50 to 70 percent higher than R-22
Cooling Capacity40-60 percent higher than R-22
Discharge Temperature10F lower than R-22
Energy EfficiencyR-410A units can be designed to meet U.S. Department of Energy guidelines of 12 to 14 SEER
LubricantPOE

Because of the higher pressure, more system components have been redesigned with increased wall thickness. When servicing this equipment, make sure you use reversing valves, expansion valves, filter-driers and other components specifically designed for R-410A.

In addition to increased pressure rating, the expansion valve flow areas required to provide the same tonnage as R-22 will be about 15 percent smaller use the correctly rated R-410A expansion valve. R-410A is a blend of two refrigerants. To achieve optimum performance, remove as a liquid from the cylinder. Consult your DuPont distributor or OEM for special equipment recommendations

Like R-22, R-410A is non-flammable at normal room temperatures, but like R-22 it can become combustible if mixed with air at elevated temperature and/or pressure. Do not mix R-410A with air for leak testing or other purposes. Instead use a mixture of R-410A and nitrogen for leak testing.

Keep pressure in perspective. The vapor pressure of R-410A is higher than R-22 at 70F. But these pressures are lower than those of other gages (e.g. oxygen) that you may be familiar with and use routinely.

SDS SHEET